In order to create a plastic valve that can consistently operate at 15 bar, Hunter relies on only materials that are both time and contractor proven. Created to handle the wide range of conditions different sites will bring, the ICV valve includes both a fabric reinforced EPDM diaphragm and seat, and flow control as standard features. It can consistently withstand pressures of up to 15 bar while handling the continual hammer that such forces will produce. Plus, it’s exceptionally easy to service, with bonnet bolts that can be loosened and tightened using a variety of common contractor tools. A Filter Sentry™ option is also available for applications that involve dirty water. The Filter Sentry™ system keeps the the valve filter screen free of debris commonly found in non-potable water sources.

KEY BENEFITS
  • Optional Filter Sentry™ scours the filter screen in dirty water conditions

  • External/internal manual bleed allows for quick and easy activation at the valve

  • Glass-filled nylon construction provides high pressure rating and reliability

  • Double-beaded diaphragm seal design ensures leak-free performance

  • Fabric-reinforced EPDM diaphragm and seat ensure greater performance in all water conditions

  • Captive bonnet screws eliminate the possibility of lost parts during disassembly

  • Triple-tool bonnet screws are compatible with standard or Phillips screwdrivers as well as a nut driver

  • Encapsulated solenoid with captive plunger used on every Hunter valve provides hassle-free service

  • Flow control maximises efficiency and prolongs the life of the system

ADVANCED FEATURES


FLOW CONTROL

Maximize efficiency and prolong the life of a system by fine tuning flow and pressure for each zone.

FILTER SENTRY™

Filter Sentry scours the filter clean with a wiper that slides up and covers the entire screen when the valve opens. Even more, the wiper continues to scrub the filter's upper part during valve operation. Filter Sentry can be added after the valve is installed as well.

ACCU SYNC® PRESSURE REGULATION

Avoid sprinkler over-pressure conditions and experience significant water savings with Hunter's Accu Sync pressure regulator. This option is available in adjustable pressure or fixed pressure models.

RECLAIMED WATER IDENTIFICATION

Violet tags and handles are an option for a clear, quick, and simple method of identifying the use of non-potable water.

VALVE MODELS

PGV-101, PGV-100JT, PGV101JT

  • Reclaimed Water Handle P/N: 269205

PGV-151, PGV-201

  • Reclaimed Water Handle P/N: 607105

ICV101, ICV151, ICV201

  • Reclaimed Water Handle P/N: 561205

ICV301

  • Reclaimed Water Handle P/N: 515005

 

 
ICV Pressure Loss in Bar
Flow 1" 1½" 2" 3"
m³/hr Globe Globe Globe Globe Angle
0.05 0.1        
0.1 0.1        
0.3 0.1        
1.0 0.2        
2.5 0.2        
3.5 0.2        
4.5 0.2 0.1      
7.0 0.4 0.1      
9.0 1.0 0.1 0.1    
11.0   0.2 0.1    
13.5   0.2 0.1    
17.0   0.3 0.1    
20.5   0.4 0.2    
23.0   0.5 0.3    
27.0   0.7 0.4    
30.5   0.9 0.5    
34.0   1.2 0.6 0.2 0.1
40.0     0.9 0.2 0.2
45.5     1.2 0.3 0.2
51.0       0.3 0.3
57.0       0.4 0.4
62.5       0.5 0.5
68.0       0.6 0.6
 
 
ICV Pressure Loss in KPA
Flow 1" 1½" 2" 3"
l/min Globe Globe Globe Globe Angle
1 14        
2 14        
4 14        
20 17        
40 20        
60 20        
75 20 9.6      
115 62 10      
150 139 12 5    
190   15 7    
225   18 9.3    
280   26 14    
340   37 20    
380   46 26    
450   65 36    
510   84 47    
565   104 57 16 12
660     79 22 17
750     103 29 23
850       38 30
950       47 38
1050       58 47
1135       69 56
 